These guidelines outline FRV’s position on specific building and dangerous goods related issues.
NUMBER | NAME |
GL-01 | The Installation of FRV Emergency Telephone and Leaky Cable Communication Systems
GL-01 – The Installation of Emergency Telephone and In-Building Communication Systems
(opens in a new window)
|
GL-02 | Communication Pillars in Major Buildings Guideline currently under review with the Fire Safety Advisory Group |
GL-03 | Car Parks without Sprinkler Systems
GL-03 - Carparks without sprinkler systems
(opens in a new window)
|
GL-04 | Street Hydrants
FRV Fire Safety Guideline - GL-04 - Street Hydrants
(opens in a new window)
|
GL-05 | LPG Tank Installations
FRV Fire Safety Guideline - GL-05 - LPG Tank Installations (pdf)
(opens in a new window)
|
GL-06 | Tactical Fire Plans and 'As Installed' Drawings
FRV Fire Safety Guideline - GL-06 - Tactical Fire Plans and As-Installed Drawings (pdf)
(opens in a new window)
|
GL-07 | Single Stair High Rise Building Solutions FRV has withdrawn its support to the development of fire performance solutions pertaining to high-rise building designs that exceed 25 metres in effective height, which are only proposed to be provided with a single stair. FRV may alter this position in unique circumstances. |
GL-11 | Fluorinated Fire Fighting Foams
FRV Fire Safety Guideline - GL-11 - Fluorinated Fire Fighting Foams (pdf)
(opens in a new window)
|
GL-12 | Control of Fire Water Run Off
FRV Fire Safety Guideline- GL-12 - Control of Fire Water Run Off
(opens in a new window)
|
GL-13 | Hardstand and Emergency Vehicular Access for Fire Fighting Appliances
GL-13 - Hardstand and Emergency Vehicular Access for Firefighting Appliances
(opens in a new window)
|
GL-14 | Decommissioning of Sites Containing Dangerous Goods
FRV Fire Safety Guideline - GL-14 - Decommissioning of Sites Containing Dangerous Goods (pdf)
(opens in a new window)
|
GL-15 | Proposed Omission of Fire Brigade Booster Connection from Automatic Fire Sprinkler Systems Serving Specific Accommodation Buildings
Proposed Omission of Fire Brigade Booster Connection from Automatic Fire Sprinkler Systems Serving Specific Accommodation Buildings
(opens in a new window)
|
GL-17 | Fire Brigade Intervention Model (FBIM) – General Provisions
FRV Fire Safety Guideline - GL-17 - Fire Brigade Intervention Model (FBIM) - General Provisions (pdf)
(opens in a new window)
|
GL-19 | Fire Protection for Open Yard Storage
Fire Protection for Open Yard Storage
(opens in a new window)
|
GL-20 | Fire Brigade Intervention Model (FBIM) Dangerous Goods Sites & Major Hazard Facilities
FRV Fire Safety Guideline - GL-20 -Fire Brigade Intervention Model (FBIM) Dangerous Goods Sites & Major Hazard Facilities
(opens in a new window)
|
GL-21 | Structural Fire Safety / Dangerous Goods Compliance Issues
Structural Fire Safety / Dangerous Goods Compliance Issues
(opens in a new window)
|
GL-22 | Feed Hydrant and Booster Assembly Enclosures
Feed Hydrant and Booster Asssembly Enclosures
(opens in a new window)
|
GL-23 | Early Childhood Facilities
GL-23 - Early Childhood Facilities
(opens in a new window)
|
GL-24 | Fire Service Isolation Valve Monitoring Devices
GL-24 - Fire Service System Monitoring
(opens in a new window)
|
GL-25 | Fire Main Valve Isolation Tools
GL-25 - Fire Main Valve Isolation Tools
(opens in a new window)
|
GL-27 | Planning Guidelines for Emergency Vehicle Access and Minimum Water Supplies within the Fire Rescue Victoria District Guideline currently under review with the Fire Safety Advisory Group – for enquires please contact FRV. |
GL-28 | In Line Metering of Water Used for Fire Protection
FRV Fire Safety Guideline - GL-28 - In-Line Metering for Water Used for Fire Protection
(opens in a new window)
|
GL-29 | Identification of street hydrants for firefighting purposes Guideline currently under review with the Fire Safety Advisory Group – for enquiries please contact FRV. |
GL-30 | The Application of AS 1940 2004 Storage and Handling of Flammable and Combustible Liquids
FRV Fire Safety Guideline - GL-30 - The Application of AS 1940-2004 Storage and... (pdf)
(opens in a new window)
|
GL-31 | Use of Lifts for Evacuation
FRV Fire Safety Guideline - GL-31 - Use of Lifts for Evacuation (pdf)
(opens in a new window)
|
GL-32 | Buildings Incorporating Automated Vehicle Parking Systems (AVPS)
Buildings Incorporating Automated Vehicle Parking Systems (AVPS)
(opens in a new window)
|
GL-33 | Performance Based Design Within The Built Environment 2011 Guideline currently under review with the Fire Safety Advisory Group – for enquiries please contact FRV. |
GL-33A | This guideline has been withdrawn from circulation. |
GL-35 | Hydrostatic Testing of Fire Hydrant Systems Without Booster Connections
Hydrostatic Testing of Fire Hydrant Systems Without Booster Connections
(opens in a new window)
|
GL-36 | Indoor Pyrotechnic Displays
FRV Fire Safety Guideline - GL-36 - Indoor Pyrotechnic Displays (pdf)
(opens in a new window)
|
GL-37 | Indoor Storage of New or Used Tyres Guideline currently under review with the Fire Safety Advisory Group – for enquiries please contact FRV. |
GL-38 | Decommissioning of Fire Hydrant and Sprinkler Systems
FRV Fire Safety Guideline - GL-38 - Decommissioning of Fire Hydrant and Sprinkler Systems (pdf)
(opens in a new window)
|
GL-42 | Open Air Storage of New or Used Tyres Guideline currently under review with the Fire Safety Advisory Group – for enquiries please contact FRV. |
GL-43 | Outdoor Storage of Baled Waste Paper Guideline currently under review with the Fire Safety Advisory Group – for enquiries please contact FRV. |
GL-45 | Acoustic Separation of Fire Pump Room
FRV Fire Safety Guideline - GL-45 - Acoustic Separation of Fire Pump Room (pdf)
(opens in a new window)
|
GL-46 | Managing Monitored Automatic Alarm Systems in accordance with fire services’ legislation
Fire Safety Guideline - GL-46 - Managing Monitored Automatic Alarm Systems in accordance with fire services’ legislation
(opens in a new window)
|
GL-47 | The Use of Impulse Fan Systems in Enclosed Car Park Buildings -
FRV Fire Safety Guideline - GL-47 - The Use of Impulse Fan Systems in Enclosed Carparks (pdf)
(opens in a new window)
|
GL-50 | Emergency Planning for Combustible Recyclable and Waste Material Stored in Intermodal Freight Containers
Emergency Planning for Combustible Recyclable and Waste Material Stored in Intermodal Freight Containers
(opens in a new window)
|
GL-52 | The development of pre-incident plan (PIP) for major hazard facilities (MHF) and dangerous goods sites
FRV Fire Safety Guideline - GL-52 - The development of pre-incident plans for major hazard facilities and dangerous goods sites
(opens in a new window)
|
GL-53
| Renewable Energy Facilities - Design Guidelines and Model Requirements This document is produced by CFA’s Specialist Risk and Fire Safety Unit. FRVs Fire Rescue Commissioner supports the adoption and implementation of this document throughout Victoria.
Design Guidelines and Model Requirements Renewable Energy Facilities
(opens in a new window)
|
GL-54 | Fire Safety Study The purpose of this guideline is to provide industry with high-level information on the development of a Fire Safety Study (FSS) for a facility. This includes information relevant to dangerous goods, hazardous materials, 'relevant materials' under Schedule 14, battery energy storage systems (BESS) and waste recycling processes.
GL-54 Fire Safety Study (Final Version) 240724
(opens in a new window)
|
Updated